JNMI Calibration and Measuring
Laboratories |
 |
|
|
|
|
General Overview |
|
JNMI comprises 14 laboratory disseminated between primary and secondary
level. We are concerned in providing an adequate measuring and
calibration services via traceable calibrated references in both its
primary and secondary level to satisfy the national and regional needs,
thus our laboratory divisions can be summarized as follows: |
|
-
National Primary Laboratories , which comprise
national measurement standards that are considered the most accurate
measuring standards on the national level in the following fields:
-
Electrical measurement such as measurement of
voltage, current, resistance, capacitance, Inductance , frequency
and time.
-
Physical and mechanical measurement such as
Temperature , Humidity, Dimension, Pressure, Mass, and Force.
-
The secondary laboratories , which comprise a
less accurate measuring standards, providing calibration services in
the fields of the electrical, physical and mechanical measurement as
well as Power , flow, volume, speed, luminance, and biomedical
measurement equipment.
|
|
|
|
|
|
Electrical Metrology Division |
|
|
|
|
|
Overview
Our Electrical Calibration Laboratories are accredited by The German
Accreditation Body DAkkS GERMANY. The Registration Number
is :
DK15025-01 and Fully comply with the International Standard ISO/IEC
17025 for all issued calibration certificates , and is also ISO
9001:2000 certified |
|
|
|
|
|
|
-
The Fundamental Electrical Laboratory
,for calibration and measuring, consists the following:
|
-
National Primary laboratory for electrical measurement and
calibration , which has the following functions:
|
|
 |
-
maintain and assure the traceability of the National
Measurement Standards of DC voltage, DC current, AC current, AC
voltage, resistance, capacitance, and inductance
-
calibration of a highly accurate and reliable
equipments related to these national units
-
conducts technical consultancy, training, and advice
in the electrical field
-
research development and projects
|
|
|
The
national reference standards for this National Primary Laboratory are: |
|
|
-
Four voltage cells that varies from 1.018 to 10.018,
and with an accuracy of 1ppm
-
Eleven calibration resistors that ranges from 1 ohm
to 19M ohm, and with an accuracy that varies from 1ppm to15ppm for
every 1 ohm resistance
-
Four calibration capacitors that ranges from 1pF to
10000pF with an accuracy of 0.0002 pF to 0.0016 mF
-
Six calibration inductance that ranges from 100uH to
10H and with an accuracy that varies from 0.12 μH to 0.027 H
|
|
 |
-
Secondary Laboratory for electrical measurement and calibration
, which function is to calibrate less accurate equipments using
reference standards.
|
|
|
|
|
|
|
-
Frequency and time calibration and
measuring laboratory, consists the following:
|
-
National Primary Laboratory for Time and Frequency measurement and
calibration , which has the following functions:
|
|
 |
-
Maintain and assure the traceability of the National
Measurement Standards of Frequency and Time
-
calibration of a highly accurate and reliable
equipments related to these national units
-
conducts technical consultancy, training, and advice
in the frequency and time field
-
research development and projects
|
|
|
The
national reference standards for this National Primary laboratory are:
reference frequency generator (cesium oscillator), and rubidium
oscillator, as will as GPS system that has an accuracy of 5x10-15 |
|
|
|
|
|
|
-
Secondary laboratory for Time & Frequency, Power
measurement and calibration which function
is to calibrate less accurate equipments using reference standard
|
|
|
|
|
|
|
|
Physical & Mechanical
Metrology Division |
|
Our Physical & Mechanical Calibration Laboratories are
accredited by The German Accreditation Body DAkkS GERMANY. The Registration Number is :
DK15025-01 and Fully comply
with the International Standard ISO/IEC 17025 for all issued calibration
certificates , and is also ISO 9001:2000 certified: |
|
|
|
|
|
|
-
Temperature calibration and Measuring
laboratory, which consist the following:
|
-
National Primary laboratory for Temperature
measurement and calibration , which has the following functions:
|
|
 |
-
Maintain and assure the traceability of the National
Measurement Standards of Temperature
-
calibration of a highly accurate and reliable
equipments related to these national units
-
conducts technical consultancy, training, and advice
in Temperature
-
research development and projects
|
|
|
The national reference standards for this National
Primary Laboratory are: |
|
|
-
eight fixed point cells that represent part of the
ITS-90 that range from 0.01ºC to 1084.62ºC with an accuracy of 16 mK
to 800 mK
-
resistance temperature detector represented by
standard platinum resistance thermometer (SPRT) with an accuracy
that can reach to 40ppm per centigrade
|
|
 |
-
Secondary laboratory for Temperature measurement
and calibration which function is to calibrate less accurate
equipments using reference standards
|
|
| |
|
|
| |
|
|
-
Humidity calibration and Measuring
laboratory, which consist the following:
|
-
National Primary laboratory for Humidity measurement
and calibration , which has the following
functions:
|
|
|
-
Maintain and assure the traceability of the National Measurement
Standards of Humidity
-
Calibration of a highly accurate and reliable equipments related to
these national units
-
Conducts technical consultancy, training, and advice in Humidity
|
|
|
The national reference standards for this National
Primary Laboratory are: |
|
|
-
Dew Point Meter (Mirror),Model MBW473 with a range from 0 to 100 % , -20 to 80 oC. with an Accuracy of 0.3 %, 0.2 oC
|
|
|
| |
|
|
-
Pressure calibration and measuring
laboratory, which consists the following:
|
-
National Primary laboratory for pressure measurement
and calibration , which has the following
functions:
|
|
 |
-
Maintain and assure the traceability of the National Measurement
Standards of Pressure
-
calibration of a highly accurate and reliable equipments related to
these national units
-
conducts technical consultancy, training, and advice in Pressure
-
research development and projects
|
|
|
National reference standards related to this lab: |
|
|
|
|
|
|
-
Secondary Secondary laboratory for pressure
measurement and calibration Which function is to calibrate less
accurate equipments using reference standards
|
|
|
| |
|
|
-
Mass and Balance calibration and
Measuring laboratory, which consist the following:
|
-
National Primary Laboratory for mass measurement and
calibration , which has the following
functions:
|
|
 |
-
Maintain and assure the traceability of the National
Measurement Standards of Mass
-
Calibration of a highly accurate and reliable
equipments related to these national units
-
Conduct technical consultancy, training, and advice
in Mass and Weight
-
research development and projects
|
|
|
National standards related to this laboratory: |
|
 |
|
|
|
-
Secondary laboratory for mass measurement and
calibration Which function is to calibrate
less accurate equipments using reference standards
|
|
| |
|
| |
|
|
-
Dimension calibration and measuring
laboratory, which consists the following:
|
-
National Primary Laboratory for length measurement
and calibration, which has the following
functions:
|
|
 |
-
Maintain Maintain and assure the traceability of the
National Measurement Standards of Length
-
Calibration of a highly accurate and reliable
equipments related to these national units
-
Conduct technical consultancy, training, and advice
in Length
-
research development and projects
|
|
|
National reference standards related to this laboratory: |
|
 |
|
|
|
-
Secondary laboratory for length measurement and
calibration Which function is to calibrate
less accurate equipments using reference standards
|
|
| |
|
| |
|
|
-
Force and Hardness calibration and
measuring laboratory, which consists the following:
|
-
National Primary Laboratory for force measurement and
calibration, which has the following
functions:
|
|
 |
-
Maintain and assure the traceability of the National
Measurement Standards of Force and Hardness
-
Calibration of a highly accurate and reliable
equipments related to these national units
-
Conduct technical consultancy, training, and advice
in Force
-
research development and projects
|
|
|
The national reference devices for this laboratory: |
|
|
|
|
-
Secondary laboratory for force measurement and
calibration Which function is to calibrate
less accurate equipments using reference standards
|
|
|
| |
|
|
-
Secondary Flow and Volume
Laboratory for calibration and measuring; which has the following
functions:
|
-
calibration of flow measuring devices with a maximum
range of 1000L/min and with an accuracy that can reach to 0.2%
-
calibration of volume measuring devices with a
maximum range that can reach to 200L and an accuracy of 1%
-
Conduct technical consultancy, training, and advice
in Flow and Volume
-
research development and projects
|
|
 |
| |
|
|
-
Secondary laboratory for
Biomedical Equipments measurement and calibration ; that has the
following functions:
|
-
Calibrate biomedical equipment and clinical devices
such as ECG tester, anesthesia, recovery machines clinical
thermometers and pressure devices, to guarantee the health and
safety of an individual
-
Conduct technical consultancy, training, and advice
in Biomedical equipments
-
research development and projects
|
|
 |
| |
|
| |
|
|
-
Secondary laboratory for speed s
measurement and calibration ; that has the following functions:
|
-
Calibrate speed measuring devices with a maximum
range that reach to 100000 rpm and an accuracy of 1rpm
-
Conduct technical consultancy, training, and advice
in Speed
-
research development and projects
|
|
 |
| |
|
| |
|
|
| |
|
|
-
Secondary laboratory for Luminance
measurement and calibration ; that has the following functions:
|
-
Calibrate luminance measuring devices with a maximum
range that reach to 100000 Lux and an accuracy of 2%
-
Conduct technical consultancy, training, and advice
in Luminance
-
research development and projects
|
|
 |
| |
|
| |
|
|
| |
|
|
|